Call Us: +86-510-85100000Email: swtburner@163.com
enLanguage
Low NOx Gas Burner

Low NOx Gas Burner

SWT's new generation of low NOx gas burners uses an innovative combustion head design to optimize the air/fuel ratio, staged combustion and fuel reburning technology to prevent high oxidation in the flame. The air-air mixed airflow ejected from the combustion head at a high speed forms an internal circulation of the flue gas, thereby further reducing the emission of pollutants. The technology of external circulation of flue gas makes the emission level far below the standard requirement...

Introduction

SWT's new generation of low NOx gas burners uses an innovative combustion head design to optimize the air/fuel ratio, staged combustion and fuel reburning technology to prevent high oxidation in the flame. The air-air mixed airflow ejected from the combustion head at a high speed forms an internal circulation of the flue gas, thereby further reducing the emission of pollutants. The technology of external circulation of flue gas makes the emission level far below the standard requirement.

Low NOx Gas Burner


Technical parameter

Serial Number

Project

Technical parameter

Note

1. 

Boiler t/h

10


2. 

Burner Model

THG70LN-FGR


3. 

Structure

All-in-one


4. 

Manifold size  mm

D80


5. 

Fuel

Natural Gas

8500kcal/Nm3

6. 

Gas Pressure Requirements KPa

50~70

Dynamic Pressure

7. 

Gas Pipeline

>DN80


8. 

Flue Gas External Circulation Pipeline

DN300


9. 

Adjustment Method

Electronic Proportional Adjustment


10. 

Turndown Ratio

1:5


11. 

Rated Output Power KW

1000~10500


12. 

Rated Air Consumption  Nm3/h

787

Theoretical Value

13. 

Air consumption  Nm3/h

112~1180

Theoretical Value

14. 

Motor Power KW

37


15. 

Flame Diameter mm

1060


16. 

Flame Length mm

4780


17. 

Noise dB

≤85


18. 

Configure the number of burner

1


19. 

Combustion Form

Diffusion Combustion


20. 

Burner Arrangement And Installation Angle

According To Site Layout


21. 

Ringelmann Blackness

<Ⅰ级


22. 

NOx Emissions mg/Nm3

<30


23. 

Altitude m

<500



Product Advantage

The 10-ton gas boiler needs to be equipped with a low-nitrogen burner. The SWT burner is equipped with a THG70LN-FGR low-nitrogen gas burner for the selection of a single boiler through relevant information and standards. The fuel is natural gas, and the boiler exhaust nitrogen oxide emissions Less than 30mg/m3.


This type of Low Nitrogen Gas Burner adopts low-nitrogen technologies such as staged combustion, flue gas internal circulation and flue gas recirculation (FGR for short), the control method is electronic proportional adjustment, and the valve group is Siemens double safety solenoid valve.


The new generation of THG/LN/FGR series low NOx gas burners all use electronic proportional adjustment system to ensure that the burner maintains a high level of combustion efficiency and adjustment accuracy, thereby reducing fuel consumption and saving user operating costs.

Certificate-1

Certificate2


Security Control

1. Protection from anomalous gas pressure: high or low gas pressure sends information to the combustion manager, which then sends an alert signal and halts the ignition process;

2. Protection against abnormal wind conditions: low wind conditions will convey information to the combustion management, produce an alarm signal, and halt the ignition process;

3. Protection against leaks: If a gas leak is discovered, an alert signal will be issued to halt the ignition of the combustion;

4. Protection against flameout: When flame detection detects a flameout, an alarm signal is produced to halt combustion;

5. Protection against ignition failure: If the primary fire or ignition gun fails to ignite, an alert signal is produced, and the ignition process is stopped;

6. Protection from fire detection faults: the fire detection system identifies a fire before it starts, sends out an alarm, and puts a stop to the burning process;

7. An alert signal is produced when the furnace pressure is elevated. If the pressure increases further to a very high level, the combustion will be abruptly stopped, enter the purging condition, and then reset;

8. The combustion will be abruptly stopped when the boiler malfunctions or the emergency stop signal is activated, an alarm signal will be produced, and it will enter the purging condition before being reset;

9. Power-off protection: When an external power source is abruptly interrupted, the boiler stops operating and must be restarted before it may resume operation when the power is restored;

10. Protection from blower operation interlock failure: When the blower fails, a signal for an alert is created, the furnace is shut off, and an audio and visual alarm is sent.

SWT-Equipment


Hot Tags: low nox gas burner, China, suppliers, manufacturers, factory, custom, price, cheap, OEM, for sale, made in China, Low NOx gas burners, natural gas ultra low nitrogen integrated burner, Boiler Low Nitrogen Burner, high speed low nitrogen oxide gas burner, Low Nitrogen Gas Boiler Burner, low noise integrated ultra low nitrogen burner

Send Inquiry

(0/10)