Low NOx Gas Burner
SWT's new generation of low NOx gas burners uses an innovative combustion head design to optimize the air/fuel ratio, staged combustion and fuel reburning technology to prevent high oxidation in the flame. The air-air mixed airflow ejected from the combustion head at a high speed forms an internal circulation of the flue gas, thereby further reducing the emission of pollutants. The technology of external circulation of flue gas makes the emission level far below the standard requirement...
Introduction
SWT's new generation of low NOx gas burners uses an innovative combustion head design to optimize the air/fuel ratio, staged combustion and fuel reburning technology to prevent high oxidation in the flame. The air-air mixed airflow ejected from the combustion head at a high speed forms an internal circulation of the flue gas, thereby further reducing the emission of pollutants. The technology of external circulation of flue gas makes the emission level far below the standard requirement.

Technical parameter
Serial Number | Project | Technical parameter | Note |
1. | Boiler t/h | 10 | |
2. | Burner Model | THG70LN-FGR | |
3. | Structure | All-in-one | |
4. | Manifold size mm | D80 | |
5. | Fuel | Natural Gas | 8500kcal/Nm3 |
6. | Gas Pressure Requirements KPa | 50~70 | Dynamic Pressure |
7. | Gas Pipeline | >DN80 | |
8. | Flue Gas External Circulation Pipeline | DN300 | |
9. | Adjustment Method | Electronic Proportional Adjustment | |
10. | Turndown Ratio | 1:5 | |
11. | Rated Output Power KW | 1000~10500 | |
12. | Rated Air Consumption Nm3/h | 787 | Theoretical Value |
13. | Air consumption Nm3/h | 112~1180 | Theoretical Value |
14. | Motor Power KW | 37 | |
15. | Flame Diameter mm | 1060 | |
16. | Flame Length mm | 4780 | |
17. | Noise dB | ≤85 | |
18. | Configure the number of burner | 1 | |
19. | Combustion Form | Diffusion Combustion | |
20. | Burner Arrangement And Installation Angle | According To Site Layout | |
21. | Ringelmann Blackness | <Ⅰ级 | |
22. | NOx Emissions mg/Nm3 | <30 | |
23. | Altitude m | <500 |
Product Advantage
The 10-ton gas boiler needs to be equipped with a low-nitrogen burner. The SWT burner is equipped with a THG70LN-FGR low-nitrogen gas burner for the selection of a single boiler through relevant information and standards. The fuel is natural gas, and the boiler exhaust nitrogen oxide emissions Less than 30mg/m3.
This type of Low Nitrogen Gas Burner adopts low-nitrogen technologies such as staged combustion, flue gas internal circulation and flue gas recirculation (FGR for short), the control method is electronic proportional adjustment, and the valve group is Siemens double safety solenoid valve.
The new generation of THG/LN/FGR series low NOx gas burners all use electronic proportional adjustment system to ensure that the burner maintains a high level of combustion efficiency and adjustment accuracy, thereby reducing fuel consumption and saving user operating costs.


Security Control
1. Protection from anomalous gas pressure: high or low gas pressure sends information to the combustion manager, which then sends an alert signal and halts the ignition process;
2. Protection against abnormal wind conditions: low wind conditions will convey information to the combustion management, produce an alarm signal, and halt the ignition process;
3. Protection against leaks: If a gas leak is discovered, an alert signal will be issued to halt the ignition of the combustion;
4. Protection against flameout: When flame detection detects a flameout, an alarm signal is produced to halt combustion;
5. Protection against ignition failure: If the primary fire or ignition gun fails to ignite, an alert signal is produced, and the ignition process is stopped;
6. Protection from fire detection faults: the fire detection system identifies a fire before it starts, sends out an alarm, and puts a stop to the burning process;
7. An alert signal is produced when the furnace pressure is elevated. If the pressure increases further to a very high level, the combustion will be abruptly stopped, enter the purging condition, and then reset;
8. The combustion will be abruptly stopped when the boiler malfunctions or the emergency stop signal is activated, an alarm signal will be produced, and it will enter the purging condition before being reset;
9. Power-off protection: When an external power source is abruptly interrupted, the boiler stops operating and must be restarted before it may resume operation when the power is restored;
10. Protection from blower operation interlock failure: When the blower fails, a signal for an alert is created, the furnace is shut off, and an audio and visual alarm is sent.

Hot Tags: low nox gas burner, China, suppliers, manufacturers, factory, custom, price, cheap, OEM, for sale, made in China, Low NOx gas burners, natural gas ultra low nitrogen integrated burner, Boiler Low Nitrogen Burner, high speed low nitrogen oxide gas burner, Low Nitrogen Gas Boiler Burner, low noise integrated ultra low nitrogen burner