SWT Burner organizes the working process of the Industrial Hot air burner burner for everyone:
FSG generally consists of the following parts:
Power supply: for supplying system operation and relay closing. Flame detection part: check and cut off the flame status at any time. Ignition output: supplies power to the ignition transformer to generate the spark required for ignition, and automatically shuts down after confirming normal ignition to maintain the ignition transformer. Valve control output: Open the fuel solenoid valve for ignition and combustion during ignition output or after a slight delay. Alarm output: When ignition fails or flameout occurs during normal combustion, the fuel valve can be cut off in time and an alarm signal is output. Others: Different FSGs are equipped with many different auxiliary devices according to needs, such as: Industrial burner fan pressure switch input.
Ion flame detection: Apply the principle of one-way ionization of high-temperature smoke, add an AC voltage to the flame, and confirm the flame status by detecting the presence or absence of current. Photoelectric flame detection: Use the light of the flame itself to detect the flame state through the photoelectric sensor.
Purge before ignition: Industrial Hot air burners are generally equipped with automatic ignition control devices. In order to ensure the safety of the initial ignition, fresh air can be sent into the furnace through the combustion fan to dilute and sweep the flammable gases in the furnace before formal ignition. , The purge time is related to the size of the furnace and the combustion process of the burner. Generally, the purge time is required to satisfy the furnace ventilation 4 times.www.burners-china.com