●Flame out fault When the burner is running and burning in normal operation, if the fire is suddenly extinguished, it is a flame out fault. the

1. After the flame fluctuates due to unstable gas source, extinguish the fire and deal with it; adjust the pressure and restart. 2. When the flame detector is faulty, the flame detection probe is grounded, or when it is too dirty, the normal flame cannot be detected, and the flame goes out. Treatment method: adjust the position of the probe and clean the surface of the probe. Restart. 3. The power supply is unstable or lacks phase due to circuit failure, which causes the flameout during the process. Solution: Contact an electrician to check the power supply and wiring.


●Industrial burner does not start fault Press the start button for a long time, the burner does not start external chain fault external temperature or pressure control does not reach the start lower limit; check the temperature or pressure set value.